Release notes for Version 6.11 Build 2 - DSX CableAnalyzer

Versiv™ Release Notes for Version 6.11 Build 2 (November 2023)

This update covers the DSX‐8000 CableAnalyzer™, DSX‐5000 CableAnalyzer™, DSX‐600 CableAnalyzer™, DSX-602 CableAnalyzer™, CertiFiber Pro®, OptiFiber Pro® modules, FI-1000 FiberInspector™ Pro and FI-3000 FiberInspector™ Ultra. Instructions on how to update your units can be found here

NOTE: • You MUST use LinkWare PC 11.3 or later to be fully compatible with Versiv™ Version 6.11. • You MUST use Versiv Version 6.9 or later to be compatible with newly manufactured DSX-8000 modules. • You MUST use Versiv Version 6.10 or later

V6.11 Build 2 Features/Enhancements

Cable / Spec Database Changes:

Added Limits

  • EN MTPL

  • IEC 14763-3:2024 Draft

  • JIS X5153

  • Superior Essex PowerWise® 1G and 10G

Updated Limits

  • JIS (+All) now equivalent to ISO limits for TCL on shielded cables

  • Removed obsolete TIA-568.3-D-1

Added Cables:

  • 3C3

  • Ekivalan

  • TKM

  • Windy City Wire

Updated Cables:

  • Removed obsolete TrueCables folder

  • Updated Berk-Tek and Leviton cables

  • Updated HCS-DataLink cables

 

Versiv™ Release Notes for Version 6.9 Build 2 (April 2023)

NOTE:

You MUST use LinkWare PC 11.2 or later be compatible with Versiv™ (TFS) Version 6.9.

You MUST use Versiv Version 6.9 or later to be compatible with newly manufactured DSX-8000 modules.

V6.9 Build 2 Features/Enhancements

Cable / Spec Database Changes:

Limits

  • ISO MPTL (Modular Plug Terminated Link) and DAC (Direct Attach Channel) limits now report error for an incompatible LIA (Link Interface Adapter)

Added Cables:

  • ALANTEC S/FPT cat 7A (now under the A-LAN TECHNOLOGIE group)

  • LUX (copper and fiber)

  • RiT Tech

  • trueCABLE Indoor and Outdoor & Burial

Updated Cables:

  • Giganet

Versiv™ Release Notes for Version 6.8 Build 6 (October 2022)

This update covers the DSX‐8000 CableAnalyzer™, DSX‐5000 CableAnalyzer™, DSX‐600 CableAnalyzer™, DSX-602 CableAnalyzer™, CertiFiber Pro®, OptiFiber Pro® modules, FI-1000 FiberInspector™ Pro and FI-3000 FiberInspector™ Ultra. Instructions on how to update your units can be found here

NOTE: You MUST use LinkWare PC 11.2 or later be compatible with Versiv™ (TFS) Version 6.8.

V6.8 Build 6 Features/Enhancements

Cable / Spec Database Changes:

Limits

  • TIA-568.3-E fiber limits added

  • E2E Limits for 11801-3 Amd 1 added

  • ISO/IEC TR 11801-9909 added

  • 25GBASE-T added (IEEE 802.3bq)

  • 40GBASE-T added (IEEE 802.3bq)

  • Updated JIS X5150:2016 limits to JIS X5150:2021

  • Updated CertiFiber Pro JIS X5150:2016 limit to same as ISO/IEC 14763-3:2014

  • Belden Long Reach Limits added (please contact Belden for details)

  • Updated TCL noise floor for TIA Cable (+All Limits)

Added Cables:

  • CERTECH

  • CobiCabling

  • Derwiser

  • Gaestopas

  • Huber & Suhner

  • ORCA

  • RSCC

  • S2CEB

  • Tinifiber

  • trueCable

  • ZVK Easylan

  • Zemec

  • Zhejiang

Updated Cables:

  • Alantec

  • Berk-Tek

  • Brand-Rex (Removed at request of Leviton)

  • Cleerline

  • Eurolan

  • Excel

  • Leviton

  • Paige Datacom/Game Changer

  • Superior Essex

Enhancements:

  • When using the CertiFiber Pro set to bi-directional for LC, FC or ST, the tester will wait 3 seconds before automatically start testing again after the cables are swapped. We have increased this to 5 seconds for higher density panels, where it can take more than three seconds to fully engage the connector. To disable this feature, simply select General as the fiber connector type.

  • Allow a 3-jumper reference for the IEC 14763-3 limit

Bug fixes:

  • When selecting a CertiFiber Pro or OptiFiber Pro module, you don’t get a choice of End Type for the fiber inspection test - fixed

  • OTDR bi-directional averaging incorrectly groups widely spaced losses – fixed

  • OTDR can misreport launch event as a hidden event (rare) - fixed

Versiv™ Release Notes for Version 6.7 Build 1 (October 2021)

This update covers the DSX‐8000 CableAnalyzer™, DSX‐5000 CableAnalyzer™, DSX‐600 CableAnalyzer™, DSX-602 CableAnalyzer™, CertiFiber Pro®, OptiFiber Pro® modules,

FI-1000 FiberInspector™ Pro and FI-3000 FiberInspector™ Ultra.

Instructions on how to update your units can be found here

NOTE: You MUST use LinkWare PC 10.9 or later be compatible with Versiv™ (TFS) Version 6.7.

V6.7 Build 1 Features/Enhancements

• Resolves a hardware compatibility issue with new DSX-5000/DSX-8000 adapters

Versiv™ Release Notes for Version 6.6 Build 2 (April 2021)

This update covers the DSX‐8000 CableAnalyzer™, DSX‐5000 CableAnalyzer™, DSX‐600 CableAnalyzer™, DSX-602 CableAnalyzer™, CertiFiber Pro®, OptiFiber Pro® modules, FI-1000 FiberInspector™ Pro and FI-3000 FiberInspector™ Ultra.

Instructions on how to update your units can be found here

NOTE: You MUST use LinkWare PC 10.8 to be compatible with Versiv™ (TFS) Version 6.6

New Features/Enhancements:

 Cable / Spec Database Changes:

 Limits

  • Added Prysmian GenSpeed EfficienC limits 

  • Added Superior Essex limits 

  • Made TCL Info only for current ISO11801-9907 DA Class D, E, and Ea and added a (+ALL) option

  • Updated MPTL (+PoE) limits to include pass/fail values for Loop Resistance 

  • Added ISO MPTL Limits

  • Updated ISO 11801 Class D noise floors for NEXT and PSNEXT 

  • Corrected the TCL noise floor for TIA 100m (LA) (+ALL) Limits 

  • Updates to E2E limits to current Published version

Cables

  • Updated CommScope Copper cables 

  • Updated DINTEK cables

  • Updated InfraLan cables 

  • Updated Krugel cables 

  • Updated LEONI Kerpen GmbH cables 

  • Updated QUBIX cables

  • Adjusted the NVP value on the cable ‘1150 S/FTP Kat7A Simplex 9301 1130’ from Cobinet

  • Added Wavenet cables

  • Added Resideo Genesis cables 

  • Added Amphenol FCI cables 

  • Added Excel cables

  • Added Techline cables 

  • Added Emiter brand cables

Versiv™ Release Notes for Version 6.5 Build 5 (February 2020)

New Features/Enhancements

Bug Fixes

  • Fixed end face analysis when using the FI-1000 LCAPC bulkhead tip

  • Corrected HDTDX graph for longer (~30 m) links on Cat8 test

  • Error is now generated if Custom Test Group is selected when doing coax testing

  • Corrected Traditional Chinese translation of "Memory Status" in the Tools menu

  • Threshold values no longer remain set after changing from manual to auto PON OTDR

  • Splitter entries no longer remain set after changing from manual to auto PON OTDR

  • DSX-602 Remote will now upgrade DSX-602 Main

  • Wire Map with crossover and shield short shows wrong pinouts

  • The Wire Map for M12 connectors has the wrong pins identified

  • Update the adhesive zone ring size for FiberInspector images

  • FaultMap returns BAD LOSS THRESHOLD error

Versiv Release Notes for Version 6.4 Build 4 (October 2019)

This update covers the DSX‐8000 CableAnalyzer™, DSX‐5000 CableAnalyzer™, DSX‐600 CableAnalyzer™, DSX-602 CableAnalyzer™, CertiFiber Pro®, OptiFiber Pro® modules, FI-1000 FiberInspector™ Pro and FI-3000 FiberInspector™ Pro.

NOTE: You MUST use LinkWare PC 10.4 to be compatible with Versiv (TFS) Version 6.4.

  1. New Features/Enhancements

  • Support for the FI-3000 FiberInspector™ Pro MPO fiber inspection probe

  • Cable / Spec Database Changes:

    • Added Lan-Com's Gig-Lan cables

    • Added SOLARIX cables

    • Updated GIGAMEDIA (Conectis) cables

    • Added "LEGRAND LCS" and rename "LEGRAND" to "LEGRAND ORTRONICS"

    • Removed Cat xx Mod 1-Conn Perm. Link

    • Belden Long Reach Channel limit added to the Vendor group

    • Cat8 TCL and ELTCTL limits updated to 568.2-D standard

    • Updated limits in the Aus-NZ Region Test Group

    • Changed CommScope Link Loss Calculator uncertainty value to 0.25 dB for multimode fiber products
       

    • Limits

    • Cables

    1. Bug Fixes
      Corrected connector compensation when using the DSX-CHA-5-IX adapter with the following limits

    • ISO 11801-9907 Class D/E/EA

    • Cat 5e and Cat 6 Patch Cords|

      Removed warning when DSX-CHA-5-IX adapter is used with legitimate cross-connected adapters
      Corrected the default coax limit on the DSX-600
      Corrected the SAMPLE wire map on Outlet Configuration screen when a shielded cable is selected

     

    Versiv Release Notes for Version 6.3 Build 3 (August 2019)
    This update covers the DSX‐8000 CableAnalyzer™, DSX‐5000 CableAnalyzer™, DSX‐600 CableAnalyzer™, CertiFiber Pro®, OptiFiber Pro®, OptiFiber Pro® HDR modules, and FI‐7000.

    NOTE: You MUST use LinkWare PC 10.3 to be compatible with Versiv (TFS) Version 6.3 Build 3.

    1. New Features/Enhancements:

    • Introduction of the DSX-602

    • Added German keyboard layout

    • Cable / Spec Database Changes:

    Limits

    • Added 5GBASE-T and 2.5GBASE-T limits to DSX-600/602

    • Added ISO TR 11801-9907 Direct Attach limits

    • Corrected IEC 61300-3-35 ED.2 APC

    Cables

    • Added and amend CCM Cables database (new NVP values and two new cables)

    • Updated Berk-Tek and Nexans cables

    1. Bug Fixes

    • OptiFiber Pro HDR event detection and measurement improvements

    Versiv Release Notes for Version 6.2 Build 1 (May 2019)

    This update covers the DSX‐8000 CableAnalyzer™, DSX‐5000 CableAnalyzer™, DSX‐600 CableAnalyzer™, CertiFiber Pro®, OptiFiber Pro®, OptiFiber Pro® HDR modules, and FI‐7000.

    NOTE: You MUST use LinkWare PC 10.2 to be compatible with Versiv (TFS) Version 6.2 Build 1.

    1. New Features/Enhancements

    Limits

    • Added limits for Ericsson RDS/DAS spec in Vendor folder

    • Add TCL and ELTCTL limits to the 100 m cable testing options

    Cables

    • Added manufacturer ICC cables to cable database

    2. Bug Fixes

    • Reliability improvements

    Versiv Release Notes for Version 6.1 Build 3 (Jan. 2019)

    This update covers the DSX‐8000 CableAnalyzer™, DSX‐5000 CableAnalyzer™, DSX‐600 CableAnalyzer™, CertiFiber Pro®, OptiFiber Pro® modules and FI‐7000.

    Instructions on how to update your units can be found here.

    NOTE: You MUST use LinkWare PC 10.1 to be compatible with Versiv (TFS) Version 6.1 Build 3.

    New Features / Enhancements:

    • OTDR Span feature allows user to specify span over which limits apply

    • OTDR Event editing feature allows user to change a Loss Event into an APC connector

    • M12 X-code channel adapter support

    • Cable / Spec Database Changes:

    Limits

    • Reordered the list of ISO classes

    • Added 10BASE-T1L limits

    • Added TCL/ELTCTL to pass/fail of ISO PL and CH limits for screened cabling

    • Moved BCT-B limits to 11801 and updated

    • Added MPTL +PoE limits

    • Updated first and last connector loss values to reflect new TIA-568.3-D-1 values

    Cables

    • Updated cables for Telegaertner

    • Added Cat 8 cable from Leviton

    • Added copper cables from Wirewerx

    • Changed Norden folder name

    • Updated cables for OCC

    • Added NEXXT Solutions cablesAdded Cat 8 cables from Datwyler

    Bug Fixes:

    • OptiFiber Pro HDR event detection and measurement improvements

    • Allow M12 D-code in applicable TIA limits and Profinet 2Pr E2E limit

    • Transportation limits removed from DSX-600

    • OTDR Event Map and trace plot corrections

    • Removed Quick Test as an Averaging Time in Manual PON OTDR settings

    • Improved copper RL Channel measurement

    • Corrected translation in CertiFiber Pro Korean fiber standards

    • Improved coax measurement using RG-11

    • Corrected Cat6 Self-Test in DSX-8000

    • Corrected launch/tail/loopback cord entry with “0,0” numeric format

    • Reliability improvements

    Versiv Release Notes for Version 6.0 Build 6 (Oct. 2018)

    You MUST install LinkWare PC 10.0 before updating your Versiv (TFS) to Version 6.0 Build 6.

    This update covers the DSX‐8000 CableAnalyzer™, DSX‐5000 CableAnalyzer™, CertiFiber Pro®, OptiFiber Pro® modules and FI‐7000.

    Instructions on how to update your units can be found here

    1. New Features/Enhancements

    • OptiFiber Pro® HDR OTDR

      • The OptiFiber Pro® HDR OTDR is a high dynamic range OTDR suitable for testing single-mode passive optical networks. The OptiFiber Pro® HDR OTDR is the latest addition to the Versiv™ Cable Certification Family, continuing the Fluke Networks tradition of designing products to help data communications installers more quickly, accurately and profitably achieve system acceptance for copper and fiber jobs.

      • Optimized for FTTx/PON testing through splitters up to nx128

      • High dynamic range up to 42 dB

      • Multiple wavelengths support a variety of applications: 850, 1300, 1310, 1490,1550,1625 nm

      • Splitter detection for automated discovery of splitters and their ratios. Up to three cascaded splitters may be found or manually configured

    • OptiFiber Pro® Series OTDR

      • Macrobend detection when testing single-mode fibers with OTDR

      • OTDR Event Edit function provides the ability edit or add events – Add 0 dB events, such as perfect splices, not seen by the OTDR or change an event to the correct type: APC connector, a splice or loss event.

      • OTDR Expert Manual mode, allows the user to quickly experiment with range, pulse width, averaging time and wavelength settings to uncover details of interest

    1. Cable / Spec Database Change

    • TIA 568.2-D / Draft ISO 61935-2 Patch Cord

      • Updated to the latest published / proposed standards. Includes a reduction in NEXT requirement for the 36-45 pair combination

    • TIA 568D.2 / IEC 11801-1

      • Update the ohmic noise floor for resistance unbalanced per current standards

    • Korean Emblem Channel

      • Updated name of the Korean channel specs

    • GameChanger™ Channel

      • Added the GameChanger™ channel specs from Paige Datacom

    • Added / Updated cables from the following manufacturers.

      • 3M

      • Acome

      • Brand-Rex

      • ID

      • Infinilink Technologies

      • LAPP-Kabbel

      • Leviton

      • Molex

      • Nexans

      • Nordenco

      • Paige Datacom

      • Rodgers Communications

      • Schrack Technik

      • Siemens SIMATIC

      • ZVK

    1. Bug Fixes

    • Enhanced limits for the shield integrity algorithm

    • Improved keyboard performance

    • Improved response time as more projects are added

    Versiv (TFS) Release Notes for Version 5.6 Build 5 (July 2018)

    You MUST install LinkWare PC 9.9 before updating your Versiv (TFS) to Version 5.6 Build 5.

    This update covers the DSX‐8000 CableAnalyzer™, DSX‐5000 CableAnalyzer™, CertiFiber Pro®, OptiFiber Pro® modules, the FI‐7000 and DSX-600 CableAnalyzer™ .

    Instructions on how to update your units can be found here.

    1. New Features / Enhancements

    • Support for a new version of the GG45 adapter for the DSX-8000

    1. Cable / Spec Database Change

    • JIS X5151 Fiber Standard

    • ISO 11801-9905 standard

      • Added +All

      • Added +PoE

    • Existing limits with +All

    • Updated spec names in the database

    • Generic Cat6A S/FTP

    • Added or updated cables from the following manufacturers:

      • MMC Multimedia Connect

      • Molex

      • Vertical Cable

      • BKT Elektronik

      • Betts Telecom (Voice 4 pair Test Limit)

      • Hubbell (added copper cables / update fiber cables)

      • CCM

      • General Cables

      • Furukawa

      • InfraLan

      • DATWYLER (Update request)

      • EFB Elektronik GmB

      • Ultima

      • Nikomax Limited

      • CONNECTIX

    1. Bug Fixes

    • Loss budget calculations for two and three jumper references were updated for the ANSI/TIA-568.3-D

    • ISO E2E limits are incorrectly applying the TCL and ELCTCL limits to screened cabling

    • Set the default to "on" for Bi-directional tests in Smartloop OTDR

    • Added "Cat 7 S/FTP" to default 'last used' list

    • Support "Profinet 2pr E2E" Hybrid M12 RJ45 without warning

    Versiv (TFS) Release Notes for Version 5.5 Build 2 (March 2018)

    You MUST install LinkWare PC 9.9 before updating your Versiv (TFS) to Version 5.5 Build 2.

    This update covers the DSX‐8000 CableAnalyzer™, DSX‐5000 CableAnalyzer™, CertiFiber Pro®, OptiFiber Pro® modules, the FI‐7000 and DSX-600 CableAnalyzer™ .

    Instructions on how to update your units can be found here.

    1. New Features/Enhancements

    1. Cable / Spec Database Change

    • Generic OM5 fiber

      • Added a generic OM5 fiber

    • CommScope cables and limits

      • Added LazrSPEED Wideband OM5 fiber

      • Added SYSTIMAX limits

    • Belden cables and limits

      • Added 4K UHD media cables

      • Updated the 4K UHD limits

    • Legrand + Superior Essex

      • Added PowerWise/Clarity cables

      • Added PowerWise/Clarity  1G & 10G limits 

    • ISO 11801-9905

      • Added limits to support the new standard

    1. Bug Fixes

    • DC shield test fails when using a Permanent Link adapter on main and a Patch adapter on remote.

    • With AC Wiremap enabled, there is no “Measure” option when remote is not connected.

    • Low frequency Return Loss errors are being introduced when measurement range is 600MHz and below.

    • Set Reference does not work when using TERA permanent link or channel adapters.

    • Popup to set manual fiber grading not closing when DONE is pressed.

    • Change project screen displays overlapping text

    • Reduced the likelihood of NEXT failures when conducting channel tests

    • New fiber inspection cameras fail good end-faces

    • Double tap on test setup screen causes tester to reboot

    Versiv (TFS) Release Notes for Version 5.2 Build 1 (Sept, 2017)

    Issue Resolved:
    When there are >500 (approx.) test results stored in a project, viewing the results can hang and reboot the tester.
    Release v5.2 Build 1 resolves this issue.

    Versiv (TFS) Release Notes for Version 5.1 Build 4 (May, 2017)

    New Features/Enhancements

    • New status of “Acceptable” for Category 6A patch cord tests

    • Ability to update software from LinkWare Live when the incompatible versions message is displayed

    • Support for the use of the DSX-PLA001 adapter on the DSX-8000 module

    Cable / Spec Database Change

    • EL-3600 limits--Updated to match latest revision (version 9) from the Taiwan standards body

    • IEC 61300-3-35 2nd Edition--Added fiber limits per the specification

    • TIA-568.3-D

    • Updated to account for standard grade TRC's

    • Patch Cord Limits

    • Added >20m TIA C6A cord Limits 

    • Added >20m ISO Cat5e, Cat6 and Cat6A patch cord Limits 

    • TIA MPTL Limits - Modular Plug Terminated Links--Implemented limits for the new topology introduced in TIA- 568.2-D (Draft) Standard

    • GB50312 - China National Standard--Updated the limits to the newest version

    • Added Huawei Cat5e Channel limits

    • Added Belden’s 4K UHD Media Cable Channel limits

    • Added Extron Limits

    • Added Alcadon ECS copper cables

    Bug Fixes

    • Talk does not work using the coax adapter or when using the Main as Smart Remote

    • The Versiv  / LinkWareLive sync slowed down considerably with version V5.0

    • LinkWare Live sync generates error when trying to overwrite a random label set with > 1300 ID’s

    • Corrected Japanese translations

    • Aborting OTDR test occasionally hangs then reboots the tester

    Changes to DSX CableAnalyzer Version 5.0 Build 3 (January 2017)

    1.  New Features/Enhancements

    •  DSX-8000 CableAnalyzer™

    • The DSX-8000 CableAnalyzer™ is the first field tester independently verified and endorsed to meet all the requirements for the Category 8 field testing standard. The DSX-8000 is the latest addition to the Versiv™ Cable Certification Family, continuing the Fluke Networks tradition of designing products to help data communications installers more quickly, accurately and profitably achieve system acceptance for copper and fiber jobs.

    • Patch Cord Testing Enhancements

    • Option to turn Bi-Directional testing ON or OFF

    • Option to disable HDTDX/R (Available for all tests)

    • Option to prevent unsaved test result warning from being displayed (Available for all tests)

    • Long communications on the DSX-5000

    • Enables testing copper links up to 1km (Typically used for spool testing)

    • Automatically switches communications mode based on cable length

    • Looping single-tests no longer stop when remote is connected or disconnected

    • Prevent resistance unbalance measurements when using a bi-directional lab adapter

    • Reminder to update remote unit when a software update is installed on the main

    • Ability to set launch compensation from the home screen

    2.  Cable / Spec Database Change

    • TIA Cat 8, ISO/IEC Class I

    • Extended the limits to cover the full 2 GHz range

    • IEEE 802.3bz is now officially 2.5GBASE-T & 5GBASE-T

    • Now that the limits are official, removed ‘Draft’ from the name

    • Corning Optical Communications

    • Changed name that is listed under ‘manufacturers’

    • Custom CertiFiber Pro® Test Limit

    • Default fiber loss @ 850 nm changed from 3.5 dB/km to 3.0 dB/km

    • TIA‐568.3‐D updated

    • Multimode Test Cord Attenuation Allowance (dB) = 0.30 dB

    • ISO/IEC Class C through Class FA (+All)

    • TCL and ELTCTL curves are informational for screened cables

    • Added copper limits that extend length to 305 m.

    • Based on the 100m ISO limits of the same category

    • DE Eval Cat 5e 305m (LA)

    • DE Eval Cat 6 305m (LA)

    • DE Eval Cat 6A 305m (LA)

    • DE Eval Cat 7 305m (LA)

    • DE Eval Cat 7A 305m (LA)

    • DSX-REFMOD 5000 and DSX-REFMOD 8000 added for DSX CableAnalyzer™ Series

    3.  Bug Fixes

    • Reflectance value for APC is now reported as less than the minimum detectable reflectance value rather than “NA”

    • FAIL LED no longer flashes during software update on remote unit

    • Corrected German translation

    Changes to DSX CableAnalyzer Version 4.8 Build 1 (June 2016)

    1. Bug fixes

    • For DSX patch cord adapters only, Return Loss measurement issue reported - fixed

    Changes to DSX CableAnalyzer Version 4.7 Build 4 (June 2016)

    1. New features/enhancements

    • SYNC button for LinkWare Live added to HOME screen

      • Once results are sent to LinkWare Live, you can import them into LinkWare PC

      • In LinkWare PC, they appear the same as if you had connected via a USB cable

    2. Cable / Spec Database Change

    • Updated test limits:

      • BNT NBR 14565 (Brazilian) standards added for DSX CableAnalyze

      • JIS X5150:2016 replaces JIS X5150-2004

      • Added Automotive limits under a new folder - Transportation

    • Are you a manufacturer wanting to add your cables to the DSX/CertiFiber Pro and OptiFiber Pro? Click here for details.

    3. Bug Fixes

    • Pinch and zoom can result in the “Asset Tracking Is On” screen appearing – fixed

    • DSX frequency plot cursor will not move to the maximum frequency tested/displayed – fixed

    • When deleting all results, if there is more than 1250 results, not all results are deleted – fixed

    Changes to DSX CableAnalyzer Version 4.6 Build 2 (March 2016)

    1. New features/enhancements

    • Patch cord certification times reduced

      • Category 6A ≈ 12 seconds (NEXT and Return Loss measured in both directions)

      • Category 6 ≈ 10 seconds (NEXT and Return Loss measured in both directions)

      • Category 5e ≈ 10 seconds (NEXT and Return Loss measured in both directions)

    • Icon added to top of the screen, notifying the user if asset tracking (location of upload) has been turned on in LinkWare Live

    • New terms of agreement added for LinkWare Live when logging in for the first time

    2. Bug Fixes

    • Some poorly terminated shield patch cords were incorrectly displayed as open - fixed

    • Manual grading of FiberInspector would cause the unit to crash when saving the result - fixed

    Changes to DSX CableAnalyzer Version 4.5 Build 2 (January 2016)

    1. New features/enhancements

    • If automated copper diagnostics is available, tab displays FAULT INFO and not DIAGNOSTICS

    • Remembers the last 10 Wi-Fi networks and their passwords

    • You can now associate an e-mail address (LinkWare Live user name) with an operator name

    • Location of where Versiv was last connected to LinkWare Live (Cloud Service)

      • Will be enabled in February 2016 (there will be an option to disable this in your LinkWare Live account)

    • When deleting results, you will now be advised if they have not been exported 

    2. Cable / Spec Database Change

    • Updated test limits:

      • Added EN50173 OF-5000 Channel

      • Added EN50173 OF-10000 Channel

      • Updated length limit for EN50173 Fiber Optic Link with OS2 fiber to 10,000 m 

      • Limits with (+All) moved to their TIA or ISO folders

      • (+All) includes the following measurements

      • Balance Measurements folder removed

      • (+PoE) and (+TCL) limits removed since (+All) is a combination of the two

      • Resistance Unbalance within a pair/between pairs

      • Transverse Conversion Loss (TCL)

      • Equal Level Transverse Conversion Transfer Loss (ELTCTL)

      • Copper twisted pair test limits reduced to make selection easier

      • Added Class Fa (+All) limits

      • Added 2.5GBASE-T and 5GBASE-T draft 1.2 limits

      • EN50173

      • Added Korean Pre-Deploy 250 MHz Copper Limit

      • Added Chinese YD/T 1019 twisted pair cable limits – factory testing only

      • Informational length limits removed from Voice -1 Pair and Voice - 2 Pair, length is still reported

      • Added/updated cable types:

        • DNS twisted pair cables from LANSYST added

        • RdB twisted pair cables updated              

        • Generic U/FTP cables added

      • Are you a manufacturer wanting to add your cables to the DSX/CertiFiber Pro and OptiFiber Pro? Click here for details.

      3. Bug Fixes

      • Green pass light on remote now goes out when disconnecting from main unit

      • Looping copper tests longer than 10 minutes with a Wi-Fi dongle installed no longer causes a 

      • Connecting hardware test no longer fails Wire Map – this is for use in laboratories only

      • TIA Cat 6 (+All) test limit now applies a hard pass/fail to TCL and ELTCTL limits

      • In Portuguese, changed the following:

        • Apenas para Aprovado / Reprovado* to Apenas para Aprovado* / Reprovado

        • Da Ordem de Compra to  Separador Decimal

      • Various translation issues

      Changes to DSX CableAnalyzer Version 4.3 Build 6 (September 2015)

      1. New features/enhancements

      • Main unit can be turned into a remote unit (under the TOOLS menu) – allows FiberInspector at far end to be used

      • Resistance Unbalance between pairs added per draft 1.0 of ANSI/TIA-1152-A for all limits with (+PoE) and (+ALL)

      • Custom Outlet Configuration added – no longer need to select TIA-1005 limit for a two pair test

      • Automated software updates via LinkWare Live for future releases

      • Increase Cable ID sets from 20 to 50

      • Support for Unicode characters in Cable IDs

      • Add the ability to show password when logging into LinkWare Live

      • Screen resumes quicker after going to sleep

      2. Cable / Spec Database Change

      • Updated test limits:

        • Cat 5e Mod 1-Conn Perm. Link (+PoE)

        • Cat 6 Mod 1-Conn Perm. Link (+PoE)

        • Cat 6A Mod 1-Conn Perm. Link (+PoE)

        • 10GBASE-T + 802.3bt Draft 1.1

        • 1000BASE-T + 802.3bt Draft 1.1

        • 100BASE-TX + 802.3bt Draft 1.1

        • 10BASE-T + 802.3bt Draft 1.1

        • (+PoE) and (+All) limits now report Resistance Unbalance between pairs

        • IEEE 802.3bt added under Application folder

        • (+PoE) versions of BICSI modified single connector permanent link added under application folder

        • Add 40GBASE-ER4 noting that it has a minimum and well as maximum loss value

        • Measure ALL for laboratory technicians now applies local connector compensation for DSX-CHA004

        • Connector limits added for laboratory technicians under Other folder

        • End to End link support for standards bodies working on ISO/IEC 11801-99-2 Working Draft 3

        • Added cable types:

          • DIGITUS Professional

          • Leviton – Outside US

          • Maxaam

        • Updated cable types:

          • Belden 

          • Berk-Tek

          • Excel

        3. Bug Fixes

        • Manual Entry launch fiber compensation was recorded as Launch + Tail – fixed (Requires LinkWare 9.4 too)

        • Real time trace deletes launch compensation for SmartLoop - fixed

        • Cable IDs lists created in LinkWare using extended characters would result in a failed import to Versiv - fixed

        • Shield integrity test should only be carried out on links with four pairs – fixed

          • If there is less than four pairs, a traditional dc shield test is carried out

        • Re-test on fiber bi-directional could point to the incorrect fiber for resaving - fixed

        • Single Wire Map test under TOOLS does not check for split pairs – fixed

        • Removing an adapter deleted an unsaved result – fixed

        • Battery status may show a depleted battery when the battery still has plenty of charge (rare occurrence) – fixed

        • OptiFiber Pro may misalign a trace with virtual launch event (rare occurrence)  - fixed

        • Unplugging the USB camera after the manual grading visual quality box is displayed causes a crash – fixed

        • Removing the CertiFiber Pro during the 3 sec. fiber test and re-inserting it issues a requires service message – fixed

        • Blank select wireless list using Asus N10 Nano Wi-Fi adapter – fixed

        • After successful URL redirect when connecting to a Wi-Fi hotspot, user was presented with “3.0” – fixed

        • Various translation fixes

        Changes to DSX CableAnalyzer Version 4.2 Build 6 (April 2015)

        1. Bug fix

        • Customers updating from Version 2.1 Build 5 (August 2013) or earlier had problems with their fiber modules firmware being updated with Build 5. Build 6 resolves that issue. There are no other changes between Build 5 and Build 6. For customers who keep their units current, there is no issue.

        Changes to DSX CableAnalyzer Version 4.2 Build 5 (April 2015)

        1. New features/enhancements

        • Automated IEC 61300‐3‐35 FiberInspector test time now ≈ 1 second

        • Additions to automated diagnostics (FAULT INFO) for the DSX‐5000 CableAnalyzer:

          • Insertion Loss fails due to lubricant

          • Return Loss fails due to water in the cable

          • Location of DC contact resistance issue when Return Loss fails

        • Support for additional Wi‐Fi USB adapters:

          • TP‐LINK TL‐WN725N (Versions 1 & 2)

          • ASUS USB N10 Nano

          • NETGEAR WNA1000M

        • Wi‐Fi user‐access support (URL redirection and HTTP authentication)


        • Enhance network connectivity screens:

          • Access point strength

          • Locked and unlocked access points now displayed

          • MAC address of both RJ45 management Port and Wi‐Fi USB adapters

          • Improvement to the WEP configuration screen

        • PASS* result now shows FIX LATER/TEST AGAIN option

        • Allow non T568A and T568B Outlet Configurations for patch cord certification

        • Improved calibration reminders:

          • The initial calibration reminder for a module shipped from the factory will be one year after first use, but no more than 18‐months after the manufactured date in LinkWare PC Version 9.3.

        2. Cable / Spec Database Change

        • Updated test limits:

          • TIA Coax limit now runs to 1002 MHz.

        • Added cable types:

          • Linxcom Limited LAN Cables

          • DINTEK LAN CABLES

          • GIGANET

        • Changed names:

          • Spezialkabel München becomes SKM Skyline

        3. Bug Fixes

        • Various translation fixes

        • Crash when running Wire Map in Single Test after using the TALK feature ‐ Fixed

        • Coax length is greyed out – Fixed

        Changes to DSX CableAnalyzer Version 4.1 Build 2 (March 2015)

        1. Cable / Spec Database Change

        • ISO/IEC 14763-3:2014 updated

        Changes to DSX CableAnalyzer Version 4.0 Build 3 (November 2014)

        1. Cable / Spec Database Change

        • Added test limits Measure ALL - this will make every measurement possible to 1 GHz

        • Various Coax limits

        • Added cable types

          • METZ CONNECT (BTR)

        2. New features

        • Automated diagnostics (FAULT INFO) for the DSX-5000 CableAnalyzer

        • Support for new adapters (Available Dec 2014):

          • DSX-CHA003 COAX

          • DSX-CHA021 M12 D-Code

          • DSX-CHA012 GG45

        • Improved upload speed for LinkWare Live

        • If remote is not detected after  ≈  4 seconds, MEASURE option appears to allow a single ended measurement

        • Moved the @ symbol to the front of keyboard

        • Added # and + to the keyboard

        • Allow RJ45 to M12 patch cord testing (Requires DSX-PC5ES and DSX-CHA021 adapters)

        • Project Sync ready for LinkWare Live Professional (Jan 2015)

        3. Bug Fixes

        • Various translation fixes

        • Put units in TALK mode, running Wire Map under Single Tests causes a crash – fixed

        • No valid DNS would result in “LinkWare Live not available”, now results in “Error, please connect to an active network”

        • Could not cancel large transfers to LinkWare Live – fixed

        • Channel testing a < 0.6 m cord results in the adapter compensation being disabled – fixed

        • Sequential IDs longer than 30 characters indicate ID not in list – fixed

        4. Reported issues

        • Enabling the talk function, then running Wire Map as a single test under TOOLS > Single tests, causes the unit to crash - fixed for next Version.

        Changes to DSX CableAnalyzer Version 4.0 Build 3 (November 2014)

        1. Cable / Spec Database Change

        • Added test limits

          • Measure ALL - this will make every measurement possible to 1 GHz
            No limit lines or checking for a bad patch cord at the channel adapters
            Intended for those working in laboratories with the DSX-5000 CableAnalyzer

          • Various Coax limits

        • Added cable types

        • METZ CONNECT (BTR)

        Are you a manufacturer wanting to add your cables to the DSX/CertiFiber Pro and OptiFiber Pro? Click here for details.

        2. New features

        • Automated diagnostics (FAULT INFO) for the DSX-5000 CableAnalyzer

        • Support for new adapters (Available Dec 2014):

          • DSX-CHA003 COAX

          • DSX-CHA021 M12 D-Code

          • DSX-CHA012 GG45

        • Improved upload speed for LinkWare Live

        • If remote is not detected after  ≈  4 seconds, MEASURE option appears to allow a single ended measurement

        • Moved the @ symbol to the front of keyboard

        • Added # and + to the keyboard

        • Allow RJ45 to M12 patch cord testing (Requires DSX-PC5ES and DSX-CHA021 adapters)

        • Project Sync ready for LinkWare Live Professional (Jan 2015)

        3. Bug Fixes

        • Various translation fixes

        • Put units in TALK mode, running Wire Map under Single Tests causes a crash – fixed

        • No valid DNS would result in “LinkWare Live not available”, now results in “Error, please connect to an active network”

        • Could not cancel large transfers to LinkWare Live – fixed

        • Channel testing a < 0.6 m cord results in the adapter compensation being disabled – fixed

        • Sequential IDs longer than 30 characters indicate ID not in list – fixed

        Changes to DSX CableAnalyzer Version 3.0 Build 6 (May 2014)

        1. Cable / Spec Database Change

        • Added test limits

          • ISO C6 Cable 100m (LA)

          • ISO C6 PCable 100m (LA)

          • ISO C5e Cable 100m (LA)

          • Draft TIA Cat 6A Patch Cord limits

        • Updated test limits

        • ISO C5ePCable 100m (LA)

        • ISO C6PCable 100m (LA)

        • ISO C6A PCable 100m (LA)

        • ISO C7 PCable 100m (LA)

        • ISO C7A PCable 100m (LA)

        • Korean Pre-Deploy Res. SM translation fixed

        • ALANTEC

        • CCT Premise

        • Added cable types

        Are you a manufacturer wanting to add your cables to the DSX/CertiFiber Pro and OptiFiber Pro? Click here for details.

        2. New features

        • Warns user if results have not been exported if they try and delete them

        • Remote storage*

          • To enable beta testing, we have added this option to both Versiv and LinkWare.
            ****Remote storage will currently work for select beta customers only****

        • Improved pinch and zoom

        3. Bug Fixes

        • Various translation fixes

        • Incorrect display of PSNEXT for two pair tests – fixed (Requires LinkWare 9.0 too)

        • SAVE option may not display on SINGLE TESTS when SCAN OFF is selected – fixed

        • CONTINUE and FIX LATER options missing after Wire Map fails on AUTOTEST and SCAN ON is used – fixed

        • Single ended Wire Map test would not show short to shield – fixed

        • Incorrect error message when setting a reference on CertiFiber Pro if a wavelength is not present – fixed

        • Product registration database in Versiv could not handle more than 100 modules – fixed

        • Different IR values between wavelengths in OptiFiber Pro could result in Event Table length issues – fixed

        • Currently selected test may not be visible on CHANGE TEST window – fixed

        • Manual Entry launch compensation can result in a too short Range setting – fixed
          Module hardware version is not shown on Version Information screen – fixed

        • Results screen is not updated when importing results back in from a USB Drive – fixed

        • After Importing results from USB Drive, tapping MANAGE  button on Results screen does nothing – fixed

        • On the View All screen, the TRANSFER button did not give an audible click – fixed

        • Two pair copper test, view NEXT then tap < or > on either side of Pair to cause a crash – fixed

        • Cable ID pop-up message stating that an ID entered that is not in list when greater than 30 characters – fixed

        • Importing a new project from a USB Drive is not shown until you refresh the screen - fixed

        Changes to DSX CableAnalyzer Version 2.3 Build 2 (December 2013)

        1. Cable / Spec Database Change

        • Added test limits

        • Cat 6A Mod 1-Conn Perm. Link

        • Profinet 2pr E2E limit

        • Added cable types

        • KRUGEL EXIM

        • KEline

        • Eurolan cable

          2. New Features

        • Product Registration support (via LinkWare 8.2).

        • Single test / scanning troubleshooting tools for copper. (Wiremap, Length and Resistance).

        • Tone Generator functionality (includes wake-up of unit on the other end).

        • DSX-PLA001 support

        • Patch Cord Adapter support (5e, 6 and 6A adapters coming end Q1 2014).

        3. Bug Fixes

        • Incorrect Russian Translations - fixed

        • Incorrect delay skew calculations for 2 pair applications - fixed

        • DSX issues bad patch cord warning when DTX does not - fixed

        • Can't run test with lab adapter spec when CHA004 channel adapter is attached - fixed

        • Copper LIA Version Info should not include calibration date - fixed

        Changes to DSX CableAnalyzer Version 2.1 Build 5 (August 2013)

        1. Cable / Spec Database Change

        • Renamed limits ending in - PoE to (+PoE) to be consistent with other test limit names - no change in limit values 

        • Added to cable library

          • AT & T Cabling Systems

          • DINTEK LAN CABLES

          • SOLARIX

          • QUBIX

          • VOKA Cable

        • Updated cable library

        • HCS-DataLink

        • Nexans

        • Datwyler

        2. New Features

        • Added Czech, Hungarian, Polish, Swedish and Turkish languages

        3. Bug Fixes

        • Various language translation issues fixed